{"id":2337,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/adjustable-resistance-ballast\/"},"modified":"2025-06-27T10:31:44","modified_gmt":"2025-06-27T02:31:44","slug":"adjustable-resistance-ballast","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/tr\/urunler\/adjustable-resistance-ballast\/","title":{"rendered":"Ayarlanabilir Diren\u00e7 Balast\u0131"},"content":{"rendered":"<p>RB-3 is designed according to the following standard requirements: IEC 60929 (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T15144<\/a>), <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C78.81-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C78.81<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C82.11-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C82.11<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC62776-2014-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC62776<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T-15144<\/a> double-ended fluorescent lamp adoptting the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081<\/a> (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-10682-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T10682<\/a>) and the single-ended fluorescent lamp adoptting the IEC 60901 (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17262-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17262<\/a>)<\/p>\n<p>The RB-3 works with HFP-800 (<a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/high-frequency-power-supply.html\" target=\"_blank\" rel=\"noopener noreferrer\">Y\u00fcksek Frekansl\u0131 G\u00fc\u00e7 Kayna\u011f\u0131<\/a>\u00a0) and LPS-3 (<a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/lamp-preheat-assistant-source.html\" target=\"_blank\" rel=\"noopener noreferrer\">Auxiliary Power Supply<\/a>) T5 T\u00fcp\u00fc gibi Frekans Floresan Lambas\u0131n\u0131 test etmek i\u00e7in kullan\u0131lan bir IEC Standart Test Sistemidir. G\u00f6r\u00fcnt\u00fclemek i\u00e7in l\u00fctfen bu sayfay\u0131 ziyaret edin <a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-to-measure-the-high-frequency-fluorescent-lamp.html\" target=\"_blank\" rel=\"noopener\">Y\u00fcksek Frekansl\u0131 Floresan Lamba Nas\u0131l \u00d6l\u00e7\u00fcl\u00fcr<\/a>.<\/p>\n<p><strong>Standart:<\/strong><br \/>\nIEC 60929 (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T15144<\/a>) \u201cAC and\/or DC-supplied electronic control gear for tubular fluorescent lamps \u2013 Performance requirements (Edition 4.1; Consolidated Reprint)\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C78.81-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C78.81<\/a> \"Elektrik Lambalar\u0131 i\u00e7in Amerikan Ulusal Standard\u0131 - Kat\u0131 Hal Ayd\u0131nlatma \u00dcr\u00fcnlerinin Kormatikli\u011fi i\u00e7in \u00d6zellikler\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C82.11-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C82.11<\/a> \"Lamba \u00d6n Is\u0131tma Yard\u0131mc\u0131 Kayna\u011f\u0131 Yard\u0131mc\u0131 G\u00fc\u00e7 Kayna\u011f\u0131\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC62776-2014-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC62776<\/a> \"Do\u011frusal floresan lambalar\u0131 g\u00fc\u00e7lendirmek i\u00e7in tasarlanm\u0131\u015f \u00e7ift kapakl\u0131 LED Lambalar - G\u00fcvenlik \u00f6zellikleri\"<br \/>\nIEC 60901 (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17262-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17262<\/a>)\u201dSingle-Capped Fluorescent Lamps \u2013 Performance Requirements\u201d<\/p>\n<p><strong>\u015eartname:<\/strong><br \/>\n\u2022\u00a0Available current range: 0~0.700A<br \/>\n\u2022\u00a0Impedance range: 100~2047\u03a9<br \/>\n\u2022\u00a0Impedance tolerance range: \u00b10.5% (Under calibration current). \u00b11% (Any current between 50% calibration current)<br \/>\n\u2022\u00a0Within the range of impedance: series inductance of impedance is less than 0.1mH, parallel connection capacitance is less than 1nF<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-1080x1080.jpg\" alt=\"\" width=\"1080\" height=\"1080\" title=\"\"><\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-hfp-800-high-frequency-power-supply-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN RB-3 Adjustable Resistance Ballast \u2013 After-sales Frequently Asked Questions (FAQ)<\/a><\/span><br \/>\n<\/strong>LISUN RB-3 Adjustable Resistance Ballast were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>RB-3 is designed according to the following standard requirements: IEC 60929 (GB\/T15144), ANSI-ANSLG-C78.81, ANSI-ANSLG-C82.11, IEC62776, GB\/T-15144 double-ended fluorescent lamp adoptting the IEC 60081 (GB\/T10682) and the single-ended fluorescent lamp adoptting the IEC 60901 (GB\/T17262) The RB-3 works with HFP-800 (High Frequency Power Supply\u00a0) and LPS-3 (Auxiliary Power Supply) to be an IEC Standard Test System [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3563,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[95],"class_list":["post-2337","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-rb-3"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/posts\/2337","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/comments?post=2337"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/posts\/2337\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/media\/3563"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/media?parent=2337"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/categories?post=2337"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/tr\/wp-json\/wp\/v2\/tags?post=2337"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}