{"id":2963,"date":"2025-06-19T19:42:40","date_gmt":"2025-06-19T11:42:40","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/portable-esd-generator-portable-esd-simulation-gun\/"},"modified":"2025-06-25T10:41:16","modified_gmt":"2025-06-25T02:41:16","slug":"portable-esd-generator-portable-esd-simulation-gun","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/pl\/produkty\/portable-esd-generator-portable-esd-simulation-gun\/","title":{"rendered":"Portable ESD Generator | Portable ESD Simulation Gun"},"content":{"rendered":"<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/what-is-esd-immunity-test.html\" target=\"_blank\" rel=\"noopener\">Co to jest test ESD?<\/a><\/strong><br \/>\nThe static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The Portable ESD Generator | Portable ESD Simulation Gun is designed for the withstanding ESD performance measurement for the assessment of electrical and electronic equipment. ESD61000-2P has a LCD touch screen in both English and Chinese.\u00a0<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/what-is-an-esd-simulator-gun-used-for.html\" target=\"_blank\" rel=\"noopener\">Do czego s\u0142u\u017cy pistolet symulatora esd?<\/a><\/strong><br \/>\nPortable ESD Generator | Portable ESD Simulation Gun is highest electrostatic voltage can be up to 20 kv, which is enough to cover the most severe standard grade of electrostatic voltage requirement (the voltage requirements of the level 4 air discharge electrostatic is 15 KV). The Portable ESD Generator | Portable ESD Simulation Gun can be used for the most of electrical and electronic equipment for electrostatic discharge test, and also can ensure comparability and reproducibility of test.<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC61000-4-2-2008-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 61000-4-2<\/a>\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/EN61000-4-2-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">EN61000-4-2\/GB\/T17626.2<\/a>\u00a0\u201cElectromagnetic compatibility (EMC) \u2013 Part 4-2: Testing and measurement techniques \u2013 Electrostatic discharge immunity test\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ISO10605-2008-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ISO10605<\/a>\u00a0\u201cRoad Vehicles Test Methods for Electrical Disturbances from Electrostatic Discharge\u201d<br \/>\nGB\/T17626.2\u00a0<br \/>\nGB\/T17215.322\/IEC 62053-23:2003 \u201cElectricity metering equipment (a.c.) \u2013 Particular requirements \u2013 Part 23: Static meters for reactive energy (classes 2 and 3)\u201d<\/p>\n<p><strong>Specyfikacja:<\/strong><\/p>\n<table style=\"width: 100.043%; height: 309px;\" width=\"391\">\n<tbody>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Product Model<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">ESD61000-2P<\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"height: 29px; text-align: center; vertical-align: middle;\" width=\"204\">Napi\u0119cie wyj\u015bciowe<\/td>\n<td style=\"height: 29px; text-align: center; vertical-align: middle;\" width=\"187\">0,1~20kV\u00b15%<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Biegunowo\u015b\u0107<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">Pozytywny\/negatywny<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Energy Storage Capacitance<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">150pF\u00b110% (Replaceable)<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Discharge Resistor<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">330\u03a9\u00b15% (Replaceable)<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Czas narastania pr\u0105du<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">0,6~1ns<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Testowanie funkcji<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">Single, Count, 20pps, Air, Contact, IEC level<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Tryb wyzwalania<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">MANUAL\/AUTO<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Number of Discharge<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">1~9999<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Repetition<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">0.05s~99.99s<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"204\">Moc robocza<\/td>\n<td style=\"height: 28px; text-align: center; vertical-align: middle;\" width=\"187\">AC110~240V, 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Calibrate Report:<\/strong><\/p>\n<table style=\"width: 100.107%; height: 305px;\" width=\"682\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">Napi\u0119cie wyj\u015bciowe (kV)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Pierwszy pr\u0105d szczytowy (A)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">Pr\u0105d przy 30ns (A)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">Pr\u0105d przy 60ns (A)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">Czas narastania (ns)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">7.29<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">4.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">2.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.93<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">15.4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">7.9<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">4.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.97<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">6<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">23.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">12.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">6.5<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.97<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">8<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">29.4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">16.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">9.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.89<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">-2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">7.39<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">3.5<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">2.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.92<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">-4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">15.5<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">7.7<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">4.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.89<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">-6<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">23.4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">11.9<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">6.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.9<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"134\">-8<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">31.8<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"127\">16.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"142\">8.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"121\">0.9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>What is a ESD test? The static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The Portable ESD Generator | Portable ESD Simulation Gun is designed for the withstanding ESD performance measurement for the assessment of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3230,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[657],"class_list":["post-2963","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-esd61000-2p"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/posts\/2963","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/comments?post=2963"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/posts\/2963\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/media\/3230"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/media?parent=2963"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/categories?post=2963"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/tags?post=2963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}