{"id":2378,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60669-1-clause-18-and-19-iec-61058-1-clause-17-six-position-plug-socket-switch-life-tester\/"},"modified":"2025-07-01T17:03:12","modified_gmt":"2025-07-01T09:03:12","slug":"iec-60669-1-clause-18-and-19-iec-61058-1-clause-17-six-position-plug-socket-switch-life-tester","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/pl\/produkty\/iec-60669-1-clause-18-and-19-iec-61058-1-clause-17-six-position-plug-socket-switch-life-tester\/","title":{"rendered":"Life test of plug and socket(6 position)"},"content":{"rendered":"<p>The CZKS-6 Six Positions Plug Socket Switch Life Tester is according to the IEC 60884-1 Clause 20 and 21 (GB\/T 2099.1 Clause 20 and 21), IEC 60669-1 Clause 18 and 19 (GB 16915.1 Clause 18 and 19) and IEC 61058-1 Clause 17 (GB\/T 15092.1 Clause 17) to design and manufacture. It is suitable for the breaking capacity and normal operation life test of Plugs and socket-outlets for household and similar purposes. It is also applicable to switches for household and similar fixed electrical installations for making and breaking capacity, normal operation and endurance tests. The purpose is to evaluate whether the plug socket and switch can withstand mechanical damage and electrical fatigue destruction in normal operation, and whether there is any contact adhesion or long -term closed or disconnecting phenomenon. Checking whether it has excessive wear and other harmful consequences is a special equipment for the endurance test of plug sockets and switching electrical durability.<\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201eWtyczki i gniazda wtykowe do u\u017cytku domowego i podobnego \u2013 Cz\u0119\u015b\u0107 1: Wymagania og\u00f3lne\u201d Klauzula 20 i 21<br \/>\nIEC 60669-1 (GB 16915.1) \u201e\u0141\u0105czniki do domowych i podobnych sta\u0142ych instalacji elektrycznych \u2013 Cz\u0119\u015b\u0107 1: Wymagania og\u00f3lne\u201d Klauzula 18 i 19<br \/>\nIEC 61058-1 (GB\/T 15092.1) \u201e\u0141\u0105czniki do urz\u0105dze\u0144 \u2013 Cz\u0119\u015b\u0107 1: Wymagania og\u00f3lne\u201d Klauzula 17<\/p>\n<p><strong>Specyfikacja:<\/strong><\/p>\n<table style=\"width: 100.064%; height: 476px;\" width=\"546\">\n<tbody>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\"><strong>Model LISUN<\/strong><\/td>\n<td style=\"width: 22.3844%; text-align: center; vertical-align: middle;\" width=\"134\"><strong>CZKS-6<\/strong><\/td>\n<td style=\"width: 18.3698%; text-align: center; vertical-align: middle;\" width=\"109\"><strong>CZKS-6P<\/strong><\/td>\n<td style=\"width: 16.4234%; text-align: center; vertical-align: middle;\" width=\"97\"><strong>CZKS-6S<\/strong><\/td>\n<td style=\"width: 17.5182%; text-align: center; vertical-align: middle;\" width=\"104\"><strong>CZKS-6X<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Stanowisko pracy<\/td>\n<td style=\"width: 22.3844%; text-align: center; vertical-align: middle;\" width=\"134\">3 plug socket +3 switch<\/td>\n<td style=\"width: 18.3698%; text-align: center; vertical-align: middle;\" width=\"109\">6 plug socket<\/td>\n<td style=\"width: 16.4234%; text-align: center; vertical-align: middle;\" width=\"97\">6 switch<\/td>\n<td style=\"width: 17.5182%; text-align: center; vertical-align: middle;\" width=\"104\">Customized quantity socket+switch<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Metoda jazdy<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Kierowca cylindra, gaz powinien by\u0107 przygotowany przez klienta: 4~6 kg\/cm2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Metoda kontroli<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">PLC + du\u017cy ekran dotykowy<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Czas po\u0142\u0105czenia\/roz\u0142\u0105czenia<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">0 \uff5e 99.9 seconds\/minutes (adjustable)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Czas testu<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">0 \uff5e 999 999 razy (regulowane)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Trasa testowa<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Liniowy: -40 ~ 110 mm (ustawienie wst\u0119pne); Obr\u00f3t: 0 \uff5e 360 \u00b0 (ustawienie wst\u0119pne)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Cz\u0119stotliwo\u015b\u0107 test\u00f3w<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Liniowy: 0 \uff5e 100 mm\/s (ustawienie wst\u0119pne); Obr\u00f3t: 0 \uff5e 90 \u00b0\/s (ustawienie wst\u0119pne)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.601%; text-align: center; vertical-align: middle;\" width=\"102\">Przyk\u0142adowa oprawa<\/td>\n<td style=\"width: 74.6958%; text-align: center; vertical-align: middle;\" colspan=\"4\" width=\"444\">Standardowy, uniwersalny uchwyt, kt\u00f3ry mo\u017cna regulowa\u0107 w g\u00f3r\u0119 i w d\u00f3\u0142 (inne specjalne wersje mo\u017cna dostosowa\u0107 do wymaga\u0144 klienta)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Sugestie opcjonalne<\/strong>: When using LISUN CZKS-6 Six-Position Plug Socket Switch Life Tester, it is necessary to choose a LISUN LS-EU800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r\/min, pressure 0.7Mpa, flow 120L\/m in, 220~240V\/50Hz) or LS-US800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r\/min, pressure 0.7Mpa, flow 120L\/min, 110~120V\/60Hz).<\/p>\n<div id=\"attachment_16909\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-16909\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-400x400.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor.jpg 500w\" alt=\"\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-16909\" title=\"\"><\/p>\n<p id=\"caption-attachment-16909\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Spr\u0119\u017carka powietrza LS-EU800W2-55L<\/span><\/p>\n<\/div>\n<p><strong>Zastosowanie:<\/strong><br \/>\nAccording to the corresponding standard requirements, the CZKS-6 Six-Position Plug Socket Switch Life Tester is equipped with the corresponding load cabinet, which can be used as a life test of plug-in sockets, buttons, switching switches, corset switches, push switching switches, rotating switches (can be customized):<br \/>\n- <strong>Typowe zastosowanie 1:<\/strong> CZKS-6 with <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/load-cabinet.html\" target=\"_blank\" rel=\"noopener\">Szafa obci\u0105\u017ceniowa do testowania lamp fluorescencyjnych z zewn\u0119trznym balastem DFX-20<\/a> (6 sets or 2 sets of DFX-20-3CH, can also be selected with 40A or 60A), you can perform the plug-in socket breaking capacity and normal operation test, which fully meets IEC 60884-1 Clause 20 and 21 (GB\/T2099.1 Clause 20 and 21) test requirement.<\/p>\n<div id=\"attachment_14370\" class=\"wp-caption aligncenter\" style=\"width: 763px;\">\n<p><img decoding=\"async\" class=\"wp-image-14370 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-8.jpg\" sizes=\"(max-width: 753px) 100vw, 753px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-8.jpg 753w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-8-400x377.jpg 400w\" alt=\"\" width=\"753\" height=\"710\" aria-describedby=\"caption-attachment-14370\" title=\"\"><\/p>\n<p id=\"caption-attachment-14370\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Klauzula 20 Zdolno\u015b\u0107 wy\u0142\u0105czania<\/span><\/p>\n<\/div>\n<div id=\"attachment_14371\" class=\"wp-caption aligncenter\" style=\"width: 728px;\">\n<p><img decoding=\"async\" class=\"wp-image-14371 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4.jpg\" sizes=\"(max-width: 718px) 100vw, 718px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4.jpg 718w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4-400x352.jpg 400w\" alt=\"\" width=\"718\" height=\"632\" aria-describedby=\"caption-attachment-14371\" title=\"\"><\/p>\n<p id=\"caption-attachment-14371\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Klauzula 21 Normalna eksploatacja<\/span><\/p>\n<\/div>\n<p>- <strong>Typowe zastosowanie 2:<\/strong> CZKS-6 with <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/load-cabinet.html\" target=\"_blank\" rel=\"noopener\">Szafa obci\u0105\u017ceniowa do testowania lamp fluorescencyjnych z zewn\u0119trznym balastem DFX-20<\/a> (6 sets or 2 sets of DFX-20-3ch, can also be used with 40A or 60A), which can perform the endurance test of the normal operation of the switch, which fully meets the IEC 60669-1 Clause 19.1 and 19.2 (GB\/ T16915.1 Clause 19.1 and 19.2) test requirement.<\/p>\n<div id=\"attachment_14373\" class=\"wp-caption aligncenter\" style=\"width: 690px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14373 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-4.jpg\" sizes=\"(max-width: 680px) 100vw, 680px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-4.jpg 680w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-4-400x353.jpg 400w\" alt=\"\" width=\"680\" height=\"600\" aria-describedby=\"caption-attachment-14373\" title=\"\"><\/p>\n<p id=\"caption-attachment-14373\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Klauzula 19.1 Normalna eksploatacja<\/span><\/p>\n<\/div>\n<div id=\"attachment_14374\" class=\"wp-caption aligncenter\" style=\"width: 752px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14374 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg\" sizes=\"(max-width: 742px) 100vw, 742px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg 742w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2-400x294.jpg 400w\" alt=\"\" width=\"742\" height=\"546\" aria-describedby=\"caption-attachment-14374\" title=\"\"><\/p>\n<p id=\"caption-attachment-14374\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Klauzula 19.2<\/span><\/p>\n<\/div>\n<p>- <strong>Typowe zastosowanie 3:<\/strong> CZKS-6 with<a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/test-for-switches-intended-for-self-ballasted-loads.html\" target=\"_blank\" rel=\"noopener\"> SBLL-3P20A Test for Switches Intended for Self-ballasted Loads<\/a> (2 sets), which can perform the endurance test of the normal operation\u00a0 of the switch, which is fully meet the IEC 60669-1 Clause 19.2 (GB\/T16915.1 Clause19.3) test requirement.<\/p>\n<div id=\"attachment_14374\" class=\"wp-caption aligncenter\" style=\"width: 752px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14374 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg\" sizes=\"(max-width: 742px) 100vw, 742px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.jpg 742w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2-400x294.jpg 400w\" alt=\"\" width=\"742\" height=\"546\" aria-describedby=\"caption-attachment-14374\" title=\"\"><\/p>\n<p id=\"caption-attachment-14374\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Klauzula 19.2<\/span><\/p>\n<\/div>\n<p>- <strong>Typowe zastosowanie 4:<\/strong> CZKS-6 with<a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/tungsten-halogen-lamp-load-cabinet.html\" target=\"_blank\" rel=\"noopener\"> Szafa \u0142aduj\u0105ca lampy wolframowe\/halogenowe DFX-WD20A<\/a> (6 sets), which can perform the durability life test of the switching ability. It is fully meets the IEC 60669-1\u00a0 Clause 18(GB\/T16915.1 Clause 18) requirements.<\/p>\n<div id=\"attachment_14372\" class=\"wp-caption aligncenter\" style=\"width: 750px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14372 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-6.jpg\" sizes=\"(max-width: 740px) 100vw, 740px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-6.jpg 740w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-6-400x349.jpg 400w\" alt=\"\" width=\"740\" height=\"646\" aria-describedby=\"caption-attachment-14372\" title=\"\"><\/p>\n<p id=\"caption-attachment-14372\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Clause 18 Making and breaking capacity<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The CZKS-6 Six Positions Plug Socket Switch Life Tester is according to the IEC 60884-1 Clause 20 and 21 (GB\/T 2099.1 Clause 20 and 21), IEC 60669-1 Clause 18 and 19 (GB 16915.1 Clause 18 and 19) and IEC 61058-1 Clause 17 (GB\/T 15092.1 Clause 17) to design and manufacture. It is suitable for the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3103,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[135],"class_list":["post-2378","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-czks-6"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/posts\/2378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/comments?post=2378"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/posts\/2378\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/media\/3103"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/media?parent=2378"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/categories?post=2378"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/pl\/wp-json\/wp\/v2\/tags?post=2378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}