ESD ํ…Œ์ŠคํŠธ๋ž€ ๋ฌด์—‡์ธ๊ฐ€์š”?
The static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The Portable ESD Generator | Portable ESD Simulation Gun is designed for the withstanding ESD performance measurement for the assessment of electrical and electronic equipment. ESD61000-2P has a LCD touch screen in both English and Chinese.ย 

์—์…‹ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ฑด์€ ์–ด๋–ค ์šฉ๋„๋กœ ์‚ฌ์šฉ๋˜๋‚˜์š”?
Portable ESD Generator | Portable ESD Simulation Gun is highest electrostatic voltage can be up to 20 kv, which is enough to cover the most severe standard grade of electrostatic voltage requirement (the voltage requirements of the level 4 air discharge electrostatic is 15 KV). The Portable ESD Generator | Portable ESD Simulation Gun can be used for the most of electrical and electronic equipment for electrostatic discharge test, and also can ensure comparability and reproducibility of test.

ํ‘œ์ค€:
IEC 61000-4-2/EN61000-4-2/GB/T17626.2ย โ€œElectromagnetic compatibility (EMC) โ€“ Part 4-2: Testing and measurement techniques โ€“ Electrostatic discharge immunity testโ€
ISO10605ย โ€œRoad Vehicles Test Methods for Electrical Disturbances from Electrostatic Dischargeโ€
GB/T17626.2ย 
GB/T17215.322/IEC 62053-23:2003 โ€œElectricity metering equipment (a.c.) โ€“ Particular requirements โ€“ Part 23: Static meters for reactive energy (classes 2 and 3)โ€

์‚ฌ์–‘:

์ œํ’ˆ ๋ชจ๋ธ ESD61000-2P
์ถœ๋ ฅ ์ „์•• 0.1~20kVยฑ5%
๊ทน์„ฑ Positive/Negative
Energy Storage Capacitance 150pFยฑ10% (Replaceable)
Discharge Resistor 330ฮฉยฑ5% (Replaceable)
ํ˜„์žฌ ์ƒ์Šน ์‹œ๊ฐ„ 0.6~1ns
ํ…Œ์ŠคํŠธ ๊ธฐ๋Šฅ Single, Count, 20pps, Air, Contact, IEC level
ํŠธ๋ฆฌ๊ฑฐ ๋ชจ๋“œ MANUAL/AUTO
Number of Discharge 1~9999
Repetition 0.05์ดˆ~99.99์ดˆ
์ž‘๋™ ์ „๋ ฅ AC110~240V, 50/60Hz

Calibrate Report:

์ถœ๋ ฅ ์ „์••(kV) ์ฒซ ๋ฒˆ์งธ ํ”ผํฌ ์ „๋ฅ˜(A) 30ns(A) ์ „๋ฅ˜ 60ns(A)์—์„œ ์ „๋ฅ˜ ์ƒ์Šน ์‹œ๊ฐ„(ns)
2 7.29 4.1 2.2 0.93
4 15.4 7.9 4.3 0.97
6 23.2 12.1 6.5 0.97
8 29.4 16.2 9.3 0.89
-2 7.39 3.5 2.3 0.92
-4 15.5 7.7 4.3 0.89
-6 23.4 11.9 6.3 0.9
-8 31.8 16.1 8.2 0.9