์˜จ๋ผ์ธ ์ฑ„ํŒ…

+8615317905991

Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter

์ œํ’ˆ ๋ฒˆํ˜ธ

๋ฉ”์‹œ์ง€๋ฅผ ๋‚จ๊ฒจ์ฃผ์„ธ์š”

=

Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter

๋ฉ”์‹œ์ง€๋ฅผ ๋‚จ๊ฒจ์ฃผ์„ธ์š”

=
์ œํ’ˆ ์„ค๋ช…

The PHOTO-200 series Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter use high-precision linear optoelectronic sensor, which has the characteristics of lightweight, stable performance, high accuracy, high cost performance, and easy carrying. Widely used on-site lighting measurement, the research and development of light source products, quality monitoring of production lines, and plant factories.

์‚ฌ์–‘:

Detector Accuracy Class A (ยฑ 4%reading ยฑ 1 reading)
Reproducibility ยฑ0.5%
Display method Touch screen (can expand: PC, mobile APP)
Screen Size 1.54 โ€œIPS HD LCD touch screen
Screen type 180 degrees rotation
Communication method USBใ€Bluetooth
Charging interface Type-C
Power supply 1600mA lithium battery
Continuous work time It can be used continuously for 12 hours after one charge
Product Size 65mm*60mm*60mm
Product weight Aluminum alloy body, 100g
Secondary development Support

Order Model:

LISUN ๋ชจ๋ธ Product Name Test Parameters and Specification
PHOTO-200 Pocket Illuminance Meter Illuminance lux test range (380-780nm): 0.1-500,000lx (ยฑ0.1lx), upper and lower limit settings, sorting tests, optical change curves (PC software), illuminance, average illuminance, maximum illuminance, minimum illuminance, point illumination, illuminance transmission (%)
PHOTO-200L Pocket Brightness Meter Brightness test range (380-780nm): 0.1-500,000cd/mยฒ (ยฑ0.1cd/mยฒ), upper and lower limit settings, sorting test, light change curve (PC software), brightness, average brightness, maximum brightness, minimum brightness, points brightness, brightness transmission (%)
PHOTO-200P PPFD Sensor and Lux Meter Illuminance lx, PPFD umol/mยฒ.s (400-700nm) test range: 0.1-500,000umol/mยฒ.s (ยฑ0.01umol/mยฒ.s) , Up and down limit settings, sorting tests, optical change curves (PC software), PPFD, average PPFD, maximum PPFD, minimum PPFD, energy, transmission ratio (%), testing time
PHOTO-200DLI PPFD Sensor๏ผˆDLI) PPFD umol/mยฒ.s (400-700nm) test range: 0.1-500,000umol/mยฒ.s (ยฑ0.01umol/mยฒ.s), total amount of effective radiation umol/mยฒ.d
PHOTO-200B Blue Light Irradiance (460nm) Irradiance ฮผW/cmยฒ (peak: 460nm) test range: 0.1-200,000ฮผW/cmยฒ (ยฑ0.1ฮผW/cmยฒ), upper and lower limit settings, sorting tests, optical change curves (PC software), irradiation, average Irradiance degree, maximum Irradiance, minimum Irradiance degree, minimum Irradiance, degree Blu -ray energy ฮผJ/cmยฒ, Irradiance transmission ratio (%), testing time
PHOTO-200UV UV Irradiance Irradiance ฮผW/cmยฒ(222 nm or 254nm or 365nm) test range: 0.1-500,000ฮผW/cmยฒ (ยฑ0.01ฮผW/cmยฒ), upper and lower limit settings, sorting tests, optical change curves (PC software), Irradiance degree, average Irradiance degree, maximum Irradiance, minimum Irradiance, UV energy, radiation transmission ratio (%), testing time
PHOTO-200UVZ UV Irradiance (Multiband) Irradiance ฮผW/cmยฒ(254nm and 365nm) test range: 0.1-500,000ฮผW/cmยฒ (ยฑ0.01ฮผW/cmยฒ), upper and lower limit settings, sorting tests, optical change curve (PC software), radiation, average radiation, maximum radiation, minimum radiation, UV energy, radical transmission ratio (%), testing time
PHOTO-200R Red Light Irradiance (650nm) Irradiance ฮผW/cmยฒ (Peak: 650nm) test range: 0.1-200,000ฮผW/cmยฒ (ยฑ0.1ฮผW/cmยฒ), upper and lower limit settings, sorting tests, light change curve (PC software), irradiation, average radiation degree, maximum radiation, minimum radiation, red light energy ฮผJ/cmยฒ, radiation transmission ratio (%), testing time
PHOTO-200IR nIR Irradiance Irradiance ฮผW/cmยฒ (850 nm or 940nm) test range: 0.1-500,000ฮผW/cmยฒ (ยฑ0.01ฮผW/cmยฒ)
PHOTO-200IRZ nIR Irradiance (Multiband) Irradiance ฮผW/cmยฒ (850 nm and 940nm) test range: 0.1-500,000ฮผW/cmยฒ (ยฑ0.01ฮผW/cmยฒ)
ko_KRKO