Chat online

+8615317905991

Misurazione di foschia e trasmittanza per materiali trasparenti e semitrasparenti

Numero di prodotto:

Lasciate un messaggio

=

Misurazione di foschia e trasmittanza per materiali trasparenti e semitrasparenti

Lasciate un messaggio

=
Descrizione del prodotto

Haze Meter and Spectrophotometer HM-700 is designed for color, haze, spectral transmittance and total transmittance measurement of transparent and translucent materials such as plastic sheets, films, glass, LCD panel and touch screen, etc.

Product Introduction:
1. Comprehensive Transmission Color Parameters

Color and haze meter hascomprehensive color parameters, which can measure dozens of color parameters such as Lab, yellowness index, whiteness index, Gardner, Pt-Co / APHA / Hazen colors.

HM-700 parameter setting

HM-700 parameter setting

2. Comply with ASTM and ISO standards
The clarity and haze meter complies with both ASTM and ISO measurement standards. It can meet the following measurement standards ASTM D1003 / D1044, ISO13468 / ISO14782, JIS K7105, JIS K7361, JIS K7163 and other international standards.

HM-700 ASTM and ISO standards

HM-700 ASTM and ISO standards

3. Different Light Sources for Different Measurement Requirements
Color and haze meter provides A, C and D65 measurement light source selection, and 24 types of measurement light source for color measurement.

HM-700 standard light sources

HM-700 standard light sources

4. Compensation Measurement to Make Test Result More Accurate
It can realize the compensation measurement of transmittance and provide more accurate transmittance test results.

HM 700 Haze And Transmittance Measurement 4

5. Haze QC software as Standard Accessory
Provide powerful haze, color, and transmittance measurement and analysissoftware, which can operate on a computer to generate and print test reports.

QQ图片20220926165143

6. Seven-inch Android Touch Screen for Better Testing Experience
Android operate system and touch screen for more convenient operation and better user experience.

QQ图片20220926165256

HM-700 android program

7. Open Sample Measurement Area, Sample can be Measured Horizontally or Vertically
Open samplemeasurement area, which is no limit on sample size, you can perform horizontal or vertical measurement according to different samples.

8. Abundant Measurement Fixtures
Meet the measurement needs of different forms of sheet and liquid samples

Specifica:

Modello HM-700
Light source Haze / Transmittance: CIE-A、CIE-C、CIE-D65
Chromaticity index: A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CMF,U30,DLF,NBF,TL83,TL84
Standard ASTM D1003/D1044,ISO13468/ISO14782,JIS K 7105,JIS K 7361,JIS K 7136,GB/T 2410-08,CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7,JIS Z8722 Condition c standard
Parameters Haze (HAZE),Transmittance (T),Spectral transmittance,

CIE Lab,LCh,CIE Luv,XYZ,Yxy, , Hunter Lab MunsellMI,CMYK,Whiteness WI(ASTM E313-00,ASTM E313-73, CIE/ISO, Hunter, Taube Berger Stensby),

Yellow Index YI(ASTM D1925, ASTM E313-00, ASTM E313-73),

Tint(ASTM E313-00), Heterochromatic index Milm,

APHA, Pt-Co(Index of platinum cobalt),Gardner, Color difference (ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*94, ΔE*00)

Measuring Range 0-100% (Haze, transmittance)
Risposta spettrale CIE The spectrum functionY/V(λ)
Gamma di lunghezze d'onda 400-700nm
Wavelength Interval 10 nm
Geometry 0/d
Illumination Area and Aperture 16.5mm/21mm
Risoluzione 0.01 unit
Ripetibilità haze<10%, repeatability≤0.05;

haze≥10%, repeatability≤0.1%;

Transmittance≤0.1%

Sample Size thickness≤145mm
Display 7 InchesTouch Screen
Data Storage 20,000 values
Interfaccia USB
Potenza 110V / 220V / 240V
Working Temperature 0~45℃, Relative humidity 80% or below (at 35 ° C), no condensation
Temperatura di conservazione -25 ℃ ~ 55℃, relative humidity 80% or below (at 35 ℃), no condensation
Dimensioni dello strumento 598mm*247mm*366mm

(length * width * height)

Standard PC management software (Color QC)
Optional Measuring Fixture, Haze Standards, Transmittance Standards, 5mm / 7mm / 10mm Apertures, 40 * 10 Glass Cell

Standard:
ASTM D1003 "Metodo di prova standard per la foschia e la trasmittanza luminosa delle materie plastiche trasparenti"
ASTM D1044 “Standard Test Method for Resistance of Transparent Plastics to Surface Abrasion by the Taber Abraser”
ISO 13468 “Plastics — Determination of the total luminous transmittance of transparent materials”
ISO 14782 “Plastics — Determination of haze for transparent materials”
CIE n. 15 “Colorimetria”
ISO 7724-1 “Pitture e vernici — Colorimetria”
ASTM E1164 “Pratica standard per l'ottenimento di dati spettrometrici per la valutazione del colore dell'oggetto”
DIN 5033-7 “Colorimetria; condizioni di misura per i colori degli oggetti”
ASTM E313 “Pratica standard per il calcolo degli indici di giallo e bianco da coordinate di colore misurate strumentalmente”
ASTM D1925 “Metodo di prova per l'indice di ingiallimento delle materie plastiche”
JISK7105, JISK7361, JISK7136, JIS Z8722, GB/T2410-08

Instrument detail:

QQ图片20220926170332

QQ图片20220926170342

QQ图片20220926170348

Applicazione:
Plastic sheet, film, glass, screen, etc.
Haze Meter Application

it_ITIT