{"id":2380,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/scientific-grade-ccd-spectroradiometer\/"},"modified":"2025-06-27T14:05:44","modified_gmt":"2025-06-27T06:05:44","slug":"scientific-grade-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/fr\/produits\/scientific-grade-ccd-spectroradiometer\/","title":{"rendered":"Spectroradiom\u00e8tre CCD de qualit\u00e9 scientifique"},"content":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Rendu des couleurs des sources lumineuses LED blanches\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"La mesure du flux lumineux<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"M\u00e9thode de mesure et de sp\u00e9cification des propri\u00e9t\u00e9s de rendu des couleurs des sources lumineuses\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Mesures optiques et \u00e9lectriques des produits d'\u00e9clairage \u00e0 semi-conducteurs\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"IESNA Standard File Format for the Electronic Transfer of Photometric Data and Related information\" (Format de fichier standard de l'IESNA pour le transfert \u00e9lectronique de donn\u00e9es photom\u00e9triques et d'informations connexes)<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Mesure du maintien du flux lumineux des sources lumineuses \u00e0 DEL<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Sp\u00e9cifications relatives \u00e0 la chromaticit\u00e9 des produits d'\u00e9clairage \u00e0 semi-conducteurs pour lampes \u00e9lectriques<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(UE) 2019\/2015<\/a> \"R\u00c8GLEMENT D\u00c9L\u00c9GU\u00c9 PAR LA COMMISSION\"<\/p>\n<p><strong>Sp\u00e9cification:<\/strong><br \/>\n\u2022 CCD detector: Hamamatsu TE-cooled (Temp: -10\u00b0C \u00b10.05\u00b0C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)<br \/>\n- Pr\u00e9cision de la longueur d'onde spectrale : \u00b10,2nm, R\u00e9solution : \u00b10,1nm, Pas de balayage de l'\u00e9chantillon : \u00b10,1nm<br \/>\n- Pr\u00e9cision des coordonn\u00e9es chromatiques (\u0394x, \u0394y) : \u00b10,0015 (sous la lampe standard A)<br \/>\n- Temp\u00e9rature de couleur corr\u00e9l\u00e9e CCT : 1, 500K~100, 000K, pr\u00e9cision CCT : \u00b10.2%<br \/>\n- Indice de rendu des couleurs : 0~100.0, Pr\u00e9cision : \u00b1(0.3%rd\u00b10.3)<br \/>\n\u2022 Photometric linear: \u00b10.2%, Stray light: &lt;0.015%(600nm) and &lt;0.03% (435nm)<br \/>\n- Temps d'int\u00e9gration : 0,1ms-60s<br \/>\n- Il peut mesurer les temp\u00e9ratures \u00e0 l'int\u00e9rieur et \u00e0 l'ext\u00e9rieur de la sph\u00e8re d'int\u00e9gration.<br \/>\n\u2022 Flux testing method: spectrum, photometric, spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Mod\u00e8le LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CSWIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Longueur d'onde<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<td style=\"width: 20%;\">800-1700nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System - Questions fr\u00e9quemment pos\u00e9es apr\u00e8s-vente (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System est sur le march\u00e9 depuis plus de 10 ans. L'\u00e9quipe d'ing\u00e9nieurs LISUN a d\u00e9j\u00e0 r\u00e9sum\u00e9 la plupart des questions et r\u00e9ponses du service apr\u00e8s-vente dans le lien ci-dessus. Veuillez les lire attentivement, vous pourrez ainsi r\u00e9soudre la plupart des probl\u00e8mes par vous-m\u00eame si vous avez des questions lors de l'utilisation des instruments. LISUN continuera \u00e0 mettre \u00e0 jour ces pages et d'autres FAQ peuvent \u00eatre trouv\u00e9es dans ce lien.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[137],"class_list":["post-2380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9500c"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/posts\/2380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/comments?post=2380"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/posts\/2380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/media\/4774"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/media?parent=2380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/categories?post=2380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/fr\/wp-json\/wp\/v2\/tags?post=2380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}