{"id":2846,"date":"2025-06-19T19:41:24","date_gmt":"2025-06-19T11:41:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-61386-1-clause-12-figure-8-heat-resistance-test-device-for-cable-conduit\/"},"modified":"2025-06-25T13:12:23","modified_gmt":"2025-06-25T05:12:23","slug":"dispositivo-de-prueba-de-resistencia-termica-para-conductos-de-cables-figura-8-clausula-12-iec-61386","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/es\/productos\/dispositivo-de-prueba-de-resistencia-termica-para-conductos-de-cables-figura-8-clausula-12-iec-61386\/","title":{"rendered":"IEC 61386-1 Cl\u00e1usula 12 Figura 8 Dispositivo de prueba de resistencia al calor para conductos de cables"},"content":{"rendered":"<p>El dispositivo de prueba de resistencia al calor LS-GWC-1 para cables se utiliza para probar el rendimiento de resistencia al calor de conductos no met\u00e1licos y compuestos, de acuerdo con los requisitos de IEC 61386-1:2020 Cl\u00e1usula 12 Figura 8 (GB\/T 20041.1-2015 Cl\u00e1usula 12 Figura 8), IEC 60614:1994 (JG 3050\/ZBG 33008).<\/p>\n<p><strong>Est\u00e1ndar:<\/strong><br \/>\nIEC 61386-1 (GB\/T 20041.1) \u201cSistemas de conductos para la gesti\u00f3n de cables \u2013 Parte 1: Requisitos generales\u201d Cl\u00e1usula 12 Figura 8<br \/>\nIEC 60614 (JG 3050\/ZBG 33008) \u201cConductos para instalaciones el\u00e9ctricas \u2013 Especificaci\u00f3n \u2013 Parte 1: Requisitos generales\u201d<\/p>\n<p><strong>Especificaci\u00f3n:<br \/>\n<\/strong>\u2022 Di\u00e1metro de la varilla de acero: 6 mm<br \/>\n\u2022 Peso de la varilla de acero: 500 g<br \/>\n\u2022 Peso de impacto: 0,5 kg, 0,5 kg, 1,0 kg, 2,0 kg, 4,0 kg y 8,0 kg<br \/>\n\u2022\u00a0 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">De acuerdo con los requisitos est\u00e1ndar, los 400 \u2103 <a href=\"https:\/\/www.lisungroup.com\/products\/environmental-test-chamber\/high-and-low-temperature-humidity-chamber.html\" target=\"_blank\" rel=\"noopener\">C\u00e1mara de pruebas de alta temperatura GW-225-400<\/a> Debe seleccionarse como accesorio de apoyo.\u00a0<\/span><\/span><\/span><\/p>\n<p><strong>Instrucciones de funcionamiento:<\/strong><br \/>\nCorte el cat\u00e9ter requerido en muestras de 100 \u00b1 5 mm de longitud. Coloque las muestras junto con este instrumento en un horno durante 4 horas \u00b1 5 minutos, con la temperatura dentro del horno seg\u00fan la Tabla 2 de la norma IEC 61386-1:1996 (GB 20041.1-2005) \u00abSistemas de conductos para instalaciones el\u00e9ctricas - Parte 1: Requisitos generales\u00bb, con un error de \u00b1 2 \u00b0C.<br \/>\n\u2022 Una vez finalizada la etapa de calentamiento, levantar la varilla de acero, colocarla sobre la muestra y aplicar los pesos correspondientes para ejercer fuerza durante 24 horas \u00b1 15 minutos, asegur\u00e1ndose que la carga sea perpendicular al eje del conducto.<br \/>\nLa carga total aplicada a la muestra, incluyendo la varilla de acero, debe cumplir con la norma, y debe aplicarse en la parte media de la muestra. Posteriormente, se debe dejar enfriar la muestra a temperatura ambiente bajo la carga aplicada.<br \/>\n\u2022 Luego retire la carga e inmediatamente haga pasar el calibre correspondiente a trav\u00e9s de la muestra, que se encuentra en posici\u00f3n vertical, sin velocidad inicial y bajo su propio peso, a trav\u00e9s del conducto.<\/p>\n<div id=\"attachment_14277\" class=\"wp-caption aligncenter\" style=\"width: 810px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14277 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/11.jpg\" sizes=\"(max-width: 800px) 100vw, 800px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/11.jpg 800w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/11-400x209.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/11-768x401.jpg 768w\" alt=\"\" width=\"800\" height=\"418\" aria-describedby=\"caption-attachment-14277\" title=\"\"><\/p>\n<p id=\"caption-attachment-14277\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Tabla 2 - Rango de temperatura superior<\/span><\/p>\n<\/div>\n<div id=\"attachment_14289\" class=\"wp-caption aligncenter\" style=\"width: 780px;\">\n<p><img decoding=\"async\" class=\"wp-image-14289 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/2.jpg\" sizes=\"(max-width: 770px) 100vw, 770px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/2.jpg 770w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/2-400x318.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/2-768x611.jpg 768w\" alt=\"\" width=\"770\" height=\"613\" aria-describedby=\"caption-attachment-14289\" title=\"\"><\/p>\n<p id=\"caption-attachment-14289\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figura 8 Aparato de prueba para la prueba de resistencia<\/span><\/p>\n<\/div>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The LS-GWC-1 Heat Resistance Test Device for Cables is used for testing the heat resistance performance of non-metallic and composite conduits, in accordance with the requirements of\u00a0 IEC 61386-1:2020 Clause 12 Figure 8 (GB\/T 20041.1-2015 Clause 12 Figure 8) , IEC 60614:1994 (JG 3050\/ZBG 33008 ) . Standard: IEC 61386-1 (GB\/T 20041.1) \u201cConduit systems for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3511,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[540],"class_list":["post-2846","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-gwc-1"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts\/2846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/comments?post=2846"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts\/2846\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/media\/3511"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/media?parent=2846"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/categories?post=2846"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/tags?post=2846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}