{"id":2736,"date":"2025-06-19T19:39:14","date_gmt":"2025-06-19T11:39:14","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/withdrawal-pull-gauges-for-effectiveness-of-contact-of-bs1363-2-figure-16\/"},"modified":"2025-06-25T15:33:35","modified_gmt":"2025-06-25T07:33:35","slug":"withdrawal-pull-gauges-for-effectiveness-of-contact-of-bs1363-2-figure-16","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/es\/productos\/withdrawal-pull-gauges-for-effectiveness-of-contact-of-bs1363-2-figure-16\/","title":{"rendered":"Withdrawal Pull Gauges for Effectiveness of Contact of BS1363-2 Figure 16"},"content":{"rendered":"<p>1) Grounding minimum pull out force gauge (BS1363-2 Figure 16a): By simulating the grounding bolt insert into the socket test samples and imposing the prescribed vertical downward force (poise) to check whether the socket is fits to the standard requirements.<\/p>\n<p>2) Diversion jack minimum pull out force gauge (BS1363-2 Figure 16b): By simulating the bolt of the firing line or zero line to insert into the socket test samples and imposing the prescribed vertical downward force (poise) to check whether the socket is fits to the standard requirements.<\/p>\n<p><strong>1. Aplicaci\u00f3n:<\/strong><br \/>\nEste medidor de enchufes y tomas se utiliza principalmente para comprobar e inspeccionar si la estructura y el tama\u00f1o de los enchufes y tomas cumplen con la norma BS 1363. Se aplica principalmente en las industrias de electr\u00f3nica, electrodom\u00e9sticos, enchufes y tomas, entre otras.<\/p>\n<p><strong>2. Caracter\u00edsticas:<\/strong><br \/>\nLas dimensiones del calibre, las tolerancias, el material, la dureza y la rugosidad de la superficie cumplen con los requisitos de las normas;<br \/>\nMaterial hardness is more than 50HRC; Material thermal expansion coefficient is small,dimensions and tolerances is stable and reliable.<\/p>\n<div id=\"attachment_12912\" class=\"wp-caption aligncenter\" style=\"width: 724px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-12912 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/GNGPL-BSF16AB-A24.png\" sizes=\"(max-width: 714px) 100vw, 714px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/GNGPL-BSF16AB-A24.png 714w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/GNGPL-BSF16AB-A24-308x400.png 308w\" alt=\"\" width=\"714\" height=\"928\" aria-describedby=\"caption-attachment-12912\" title=\"\"><\/p>\n<p id=\"caption-attachment-12912\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Withdrawal Pull Gauges for Effectiveness of Contact of BS1363-2 Figure 16<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1) Grounding minimum pull out force gauge (BS1363-2 Figure 16a): By simulating the grounding bolt insert into the socket test samples and imposing the prescribed vertical downward force (poise) to check whether the socket is fits to the standard requirements. 2) Diversion jack minimum pull out force gauge (BS1363-2 Figure 16b): By simulating the bolt [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3283,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[449],"class_list":["post-2736","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-gngpl-3616"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts\/2736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/comments?post=2736"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts\/2736\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/media\/3283"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/media?parent=2736"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/categories?post=2736"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/tags?post=2736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}