{"id":2376,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60884-1-clause-24-5-figure-30-iec-61386-1-iec-60811-506-low-temperature-impact-test-device\/"},"modified":"2025-07-03T14:25:37","modified_gmt":"2025-07-03T06:25:37","slug":"iec-60884-1-clause-24-5-figure-30-iec-61386-1-iec-60811-506-low-temperature-impact-test-device","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/es\/productos\/iec-60884-1-clause-24-5-figure-30-iec-61386-1-iec-60811-506-low-temperature-impact-test-device\/","title":{"rendered":"IEC60245 Low-temperature impact device"},"content":{"rendered":"<p>The DWC-1 Low-temperature Impact Test Device is according to IEC 60884-1:2022 Clause 24.5 Figure 30 and Clause 30.5 Figure 42 (GB\/T 2099.1-2021 Clause 24.5 Figure 27 and Clause 30.5 Figure 42 ), IEC 61386-1:2020 Clause 10.3 Figure 2 (GB\/T 20041.1-2015 Clause 10.3 Figure 2), IEC 60811-506, IEC 60245-1:2008 (GB\/T 5013.1-2008) and IEC 60227-1:2024 (GB\/T 5023.1-2018). The test is used to evaluate the impact resistance of PVC insulation at low temperatures for various PVC sheathed cables, wires, flexible cords, and unsheathed parallel flexible cords.<\/p>\n<p><strong>Est\u00e1ndar:<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d Clause 24.5 Figure 30 and Clause 30.5 Figure 42<br \/>\nIEC 61386-1 (GB\/T 20041.1) \u201cConduit systems for cable management \u2013 Part 1: General requirements\u201d Clause 10.3 Figure 2<br \/>\nIEC 60811-506 \u201cElectric and optical fibre cables \u2013 Test methods for non-metallic materials \u2013 Part 506: Mechanical tests \u2013 Impact test at low temperature for insulations and sheaths\u201d<br \/>\nIEC 60245-1 (GB\/T 5013.1)\u00a0 \u201cRubber insulated cables \u2013 Rated voltages up to and including 450\/750 V \u2013 Part 1: General requirements\u201d<br \/>\nIEC 60227-1 (GB\/T 5023.1) \u201cPolyvinyl chloride insulated cables of rated voltages up to and including 450\/750 V \u2013 Part 1: General requirements\u201d<\/p>\n<p><strong>Especificaci\u00f3n:<\/strong><br \/>\n\u2022 Working temperature: -15\u2103\u00b11\u2103<br \/>\n\u2022 Impact height: 10~200mm adjustable<br \/>\n\u2022 Length of specimen: 5D~150D<br \/>\n\u2022 Material: 304 stainless steel<br \/>\n\u2022 Completion time once: 3~5s<br \/>\n\u2022 Completion number of units for once: \u22652pcs<br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It needs to be used together with<\/span><\/span><\/span> LIS\u00daN <a href=\"https:\/\/www.lisungroup.com\/products\/environmental-test-chamber\/high-and-low-temperature-humidity-chamber.html\" target=\"_blank\" rel=\"noopener\">GDJW-500D Low temperature test chamber.<\/a><\/p>\n<table style=\"width: 102.405%; height: 261px;\" width=\"771\">\n<tbody>\n<tr>\n<td style=\"width: 14.3782%; text-align: center; vertical-align: middle;\" width=\"110\"><strong>Modelo LISUN<\/strong><\/td>\n<td style=\"width: 25.5181%; text-align: center; vertical-align: middle;\" width=\"199\"><strong>DWC-1<\/strong><\/td>\n<td style=\"width: 30.3109%; text-align: center; vertical-align: middle;\" width=\"240\"><strong>DWC-2<\/strong><\/td>\n<td style=\"width: 28.2383%; text-align: center; vertical-align: middle;\" width=\"222\"><strong>DWC-3<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 14.3782%; text-align: center; vertical-align: middle;\" width=\"110\">Impact weight<\/td>\n<td style=\"width: 25.5181%; text-align: center; vertical-align: middle;\" width=\"199\">100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500g<\/td>\n<td style=\"width: 30.3109%; text-align: center; vertical-align: middle;\" width=\"240\">1000g &amp; 100g<\/td>\n<td style=\"width: 28.2383%; text-align: center; vertical-align: middle;\" width=\"222\">0.5kg, 1.0kg, 2.0kg, 6.8kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 14.3782%; text-align: center; vertical-align: middle;\" width=\"110\">Est\u00e1ndar<\/td>\n<td style=\"width: 25.5181%; text-align: center; vertical-align: middle;\" width=\"199\">IEC 60811-506, IEC 60245-1\uff08GB\/T5013.1), IEC 60227-1(GB\/T5023)<\/td>\n<td style=\"width: 30.3109%; text-align: center; vertical-align: middle;\" width=\"240\">IEC 60884-1 Clause 24.5 and Figure 30, and Clause 30.5 and Figure 42 (GB\/T2099.1 Clause 24.5 and Figure 27, and Clause 30.5 and Figure 42)<\/td>\n<td style=\"width: 28.2383%; text-align: center; vertical-align: middle;\" width=\"222\">IEC 61386-1 Clause 10.3 and Figure 2(GB\/T20041.1 Clause 10.3 and Figure 2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Nota:<\/strong> Other standards and impact weight can be customized according to requirements!<\/p>\n<div id=\"attachment_14270\" class=\"wp-caption aligncenter\" style=\"width: 954px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14270 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-5.jpg\" sizes=\"(max-width: 944px) 100vw, 944px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-5.jpg 944w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-5-400x265.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-5-768x509.jpg 768w\" alt=\"IEC 60811-1-4 Clause 8.5 Impact test at low temperature\" width=\"944\" height=\"626\" aria-describedby=\"caption-attachment-14270\" title=\"\"><\/p>\n<p id=\"caption-attachment-14270\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60811-1-4 Clause 8.5 Impact test at low temperature<\/span><\/p>\n<\/div>\n<div id=\"attachment_14271\" class=\"wp-caption aligncenter\" style=\"width: 680px;\">\n<p><img decoding=\"async\" class=\"wp-image-14271 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-3.jpg\" sizes=\"(max-width: 670px) 100vw, 670px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-3.jpg 670w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-3-390x400.jpg 390w\" alt=\"\" width=\"670\" height=\"687\" aria-describedby=\"caption-attachment-14271\" title=\"\"><\/p>\n<p id=\"caption-attachment-14271\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure 2 Impact test apparatus<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The DWC-1 Low-temperature Impact Test Device is according to IEC 60884-1:2022 Clause 24.5 Figure 30 and Clause 30.5 Figure 42 (GB\/T 2099.1-2021 Clause 24.5 Figure 27 and Clause 30.5 Figure 42 ), IEC 61386-1:2020 Clause 10.3 Figure 2 (GB\/T 20041.1-2015 Clause 10.3 Figure 2), IEC 60811-506, IEC 60245-1:2008 (GB\/T 5013.1-2008) and IEC 60227-1:2024 (GB\/T 5023.1-2018). [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3109,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[133],"class_list":["post-2376","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-dwc-1"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts\/2376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/comments?post=2376"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/posts\/2376\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/media\/3109"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/media?parent=2376"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/categories?post=2376"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/es\/wp-json\/wp\/v2\/tags?post=2376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}