{"id":2441,"date":"2025-06-19T19:35:47","date_gmt":"2025-06-19T11:35:47","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/led-integrating-sphere-spectroradiometer-system\/"},"modified":"2025-06-24T15:56:42","modified_gmt":"2025-06-24T07:56:42","slug":"led-integrationskugel-spektroradiometersystem","status":"publish","type":"post","link":"https:\/\/www.ledtestinstrument.com\/de\/produkte\/led-integrationskugel-spektroradiometersystem\/","title":{"rendered":"LED-Integrationskugel-Spektroradiometer-System"},"content":{"rendered":"<p>Das LPCE-2 (LMS-8000) ist ein LED-Messsystem mit Ulbricht-Kugel zur Bestimmung der Leistung einzelner LEDs und LED-Lampen. Die Qualit\u00e4t von LEDs wird anhand ihrer photometrischen, kolorimetrischen und elektrischen Parameter gepr\u00fcft. <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a>,\u00a0 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> , <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-79<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/OPTICAL-ENGINEERING-49-3-033602-2010-COLOR-QUALITY-SCALE-CQS-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Optical-Engineering-49-3-033602<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> Und <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA-LM-79-08-2008-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM 79-08<\/a> Gem\u00e4\u00df den Normen wird die Verwendung eines Array-Spektroradiometers mit Ulbricht-Kugel und Photometerkopf zum Testen von SSL-Produkten empfohlen. LISUN hat das LPCE-2-Testsystem f\u00fcr LED-Produkte entwickelt.<\/p>\n<p>LMS-8000AS ist eine aktualisierte Version von LMS-8000A und kann zwei Ger\u00e4te verbinden. <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener\">Ulbrichtkugeln<\/a> Gleichzeitig. Das bedeutet, dass das LMS-8000AS bequem zwischen den beiden Kugeln umschalten kann, ohne dass das Detektorkabel und die Glasfaser zwischen der gro\u00dfen und der kleinen Kugel entfernt werden m\u00fcssen.<\/p>\n<p><strong>Standard:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \u201cFarbwiedergabe von wei\u00dfen LED-Lichtquellen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \u201cDie Messung des Lichtstroms\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \u201cVerfahren zur Messung und Spezifizierung der Farbwiedergabeeigenschaften von Lichtquellen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \u201cOptische und elektrische Messungen an Festk\u00f6rperbeleuchtungsprodukten\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \u201cIESNA-Standarddateiformat f\u00fcr die elektronische \u00dcbertragung photometrischer Daten und zugeh\u00f6riger Informationen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \u201cMessung der Lichtstromerhaltung von LED-Lichtquellen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \u201cSpezifikationen f\u00fcr die Farbart von Festk\u00f6rperbeleuchtungsprodukten f\u00fcr elektrische Lampen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(EU) 2019\/2015<\/a> \u201cVON DER KOMMISSION DELEGIERTE VERORDNUNG\u201d<\/p>\n<p><strong>Systemkonfiguration:\u00a0<\/strong><br \/>\nCCD-Spektroradiometer (<a href=\"https:\/\/www.lisungroup.com\/products\/spectroradiometer\/array-ccd-spectroradiometer.html\" target=\"_blank\" rel=\"noopener\">LMS-8000A<\/a> oder LMS-8000AS), Glasfaser (<a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/optical-fiber.html\" target=\"_blank\" rel=\"noopener\">CFO \u2013 1,5 Mio.<\/a>), Digitaler Leistungsmesser (<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-ac-model.html\" target=\"_blank\" rel=\"noopener\">LS2008R<\/a>), Wechselstromquelle (LSP-500VA), Ulbricht-Kugel (<a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-sphere-with-side-assistant-opening.html\" target=\"_blank\" rel=\"noopener\">IS-1.5MA55C<\/a>\u00a0Und\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-sphere-with-holder-base.html\" target=\"_blank\" rel=\"noopener\">IS-0,3M<\/a>), Standardlichtquelle (<a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/standard-light-source.html\" target=\"_blank\" rel=\"noopener\">SLS-50W<\/a>\u00a0und SLS-10W)<\/p>\n<p><strong>Ma\u00dfnahmen:<\/strong><br \/>\n\u2022 Kolorimetrisch: Gesamte Strahlungsintensit\u00e4t, dominante Wellenl\u00e4nge, Spitzenwellenl\u00e4nge, Farbkoordinaten, Halbwertsbreite, spektrale Reinheit, korrelierte Farbtemperatur (CCT), Farbwiedergabeindex (CRI).<br \/>\n\u2022 Photometrisch: Gesamtlichtstrom, Lichtausbeute, Strahlungsleistung<br \/>\n\u2022 Elektrische Daten: Durchlassspannung, Sperrspannung, Durchlassstrom, Sperrstrom, Spannung, Stromst\u00e4rke, Leistung, Leistungsfaktor<\/p>\n<p><strong>Spezifikation:<\/strong><br \/>\n\u2022 Spektraler Wellenl\u00e4ngenbereich: 380 nm ~ 800 nm (Optional: 200 nm ~ 800 nm und 380 nm ~ 1050 nm)<br \/>\n\u2022 Spektrale Wellenl\u00e4ngengenauigkeit: \u00b10,3 nm, Wellenl\u00e4ngenreproduzierbarkeit: \u00b10,1 nm, Abtastschritte der Probe: \u00b10,1 nm<br \/>\n\u2022 Genauigkeit der Farbkoordinaten (\u0394x, \u0394y): \u00b10,003<br \/>\n\u2022 Korrelierte Farbtemperatur (CCT): 1.500 K bis 25.000 K, CCT-Genauigkeit: \u00b10,51 TP3T<br \/>\n\u2022 Farbwiedergabeindexbereich: 0~100,0, Genauigkeit: \u00b1(0,3%rd\u00b10,3)<br \/>\n\u2022 Photometrische lineare Abweichung: \u00b10,5%, Streulicht: &lt;0,015% (600 nm) und &lt;0,03% (435 nm), Integrationszeit: 0,1 ms bis 20 s<br \/>\n\u2022 Eingebaute 5000,0 mA Konstantstrom-Gleichstromquelle, die LED- und Standardlampen betreiben kann.<br \/>\n\u2022 Es kann mit einem Intensit\u00e4tsmessger\u00e4t (ITD-8000) verwendet werden, um die Intensit\u00e4t einer einzelnen LED direkt zu testen.<br \/>\n\u2022 Verbindung mit dem PC \u00fcber USB herstellen; die englische Version der Software ist unter Win7, Win8 und Win10 lauff\u00e4hig.<\/p>","protected":false},"excerpt":{"rendered":"<p>LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Measurement System for identifying the performance of single LEDs and LED lamps. LED\u2019s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84,\u00a0 CIE-13.3 , IES LM-79, Optical-Engineering-49-3-033602, IESNA LM-63-2, ANSI-C78.377 and IES LM 79-08 standards, it recommends using an array [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3136,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[196],"class_list":["post-2441","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lpce-2lms-8000"],"_links":{"self":[{"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/posts\/2441","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/comments?post=2441"}],"version-history":[{"count":0,"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/posts\/2441\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/media\/3136"}],"wp:attachment":[{"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/media?parent=2441"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/categories?post=2441"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledtestinstrument.com\/de\/wp-json\/wp\/v2\/tags?post=2441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}